Exquisite and compact shape design to maximize cold room space utilization.
More reasonable tube-row design which can greatly reduce the wind resistance and enhance the unit heat exchange efficiency.
Using customized version and enhanced type fan motor uprating the power and adjusting fan blade angle; With high tensile air duct to improve the effective range of air throw.
Eletric and water defrosting to meet the needs of multiple application scenarios.
Upgrading product material standards and production process standards to effectively raise product quality and stability.
Double-la
Tech. data for Upgraded version water defrost evaporator
Upgraded version | Old version | Defrost heater | Fan | Connection(mm) | Overall dimension (mm) | Installation dimension(mm) | ||||||
Water volume (T/h) | Water inlet/outlet (inch) | Diameter (mm) | Vlotage (W) | Air flow (m3/h) | Voltage (V) | Inlet | Outlet | A*B*C | D | E1*E2* E3*E4 | ||
DL16.7/S452-A DD12.0/S452-A DJ7.8/S452-A | DL16.7/80 DD12.0/60 DJ7.8/40 | 1.4 | G1/G2 | 2*φ450 | 2*430 (High-stretched and reinforced type ) | 2*6800 | 380 | φ16 | φ32 | 1670*730* 850 | 540 | 675*705 |
DL22.0/S452-A DD15.9/S452-A DJ9.5/S452-A | DL22.0/105 DD15.9/80 DJ9.5/55 | 1.85 | G1.5/G2.5 | 2*φ450 | 2*430 (High-stretched and reinforced type ) | 2*6800 | 380 | φ19 | φ32 | 1670*780* 850 | 590 | 675*705 |
DL25.8/S453-A DD20.0/S453-A DJ12.8/S453-A | DL25.8/125 DD20.0/100 DJ12.8/70 | 2.4 | G1.5/G2.5 | 3*φ450 | 3*430 (High-stretched and reinforced type ) | 3*6800 | 380 | φ19 | φ38 | 2080*780* 850 | 590 | 585*585*61 |
DL35.6/S453-A DD24.0/S453-A DJ15.7/S453-A | DL35.6/160 DD24.0/120 DJ15.7/85 | 2.95 | G1.5/G2.5 | 3*φ450 | 3*430 (High-stretched and reinforced type ) | 3*6800 | 380 | φ19 | φ38 | 2450*780* 850 | 590 | 710*710* 740 |
DL38.5/S454-A DD28.0/S454-A DJ18.5/S454-A | DL38.5/185 DD28.0/140 DJ18.5/100 | 3.45 | G1.5/G2.5 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ22 | Φ45 | 2800*780* 850 | 590 | 620*620* 620*650 |
DL44.0/S454-A DD32.1/S454-A DJ21.6/S454-A | DL44.0/210 DD32.1/160 DJ21.6/115 | 3.9 | G1.5/G2.5 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ22 | Φ50 | 3160*780* 850 | 590 | 710*710* 710*740 |
DL52.5/S454-A DD37.4/S454-A DJ23.8/S454-A | DL52.5/260A DD37.4/200A DJ23.8/140A | 4.8 | G2/G3 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ25 | Φ50 | 3280*780* 950 | 590 | 740*740* 740*770 |
DL52.5/S632-A DD37.4/S632-A DJ23.8/S632-A | DL52.5/260B DD37.4/200B DJ23.8/140B | 4.8 | G2/G3 | 2*φ630 | 2*850 (High-stretched and reinforced type ) | 2*10000 | 380 | Φ25 | Φ50 | 2190*930* 1110 | 700 | 925*975 |
DL52.5/S602-F DD37.4/S602-F DJ23.8/S602-F | DL52.5/260B DD37.4/200B DJ23.8/140B | 4.8 | G2/G3 | 2*φ600 | 2*1500 (Air duct type) | 2*10000 | 380 | Φ25 | Φ50 | 2190*1100* 1110 | 700 | 925*975 |
DL67.2/S455-A DD46.8/S455-A DJ29.0/S455-A | DL67.2/330A DD46.8/250A DJ29.0/170A | 6 | G2/G3 | 5*φ450 | 5*430 (High-stretched and reinforced type ) | 5*6800 | 380 | Φ25 | Φ50 | 3620*780* 1050 | 590 | 660*660*660*600*690 |
DL67.2/S633-A DD46.8/S633-A DJ29.0/S633-A | DL67.2/330B DD46.8/250B DJ29.0/170B | 6 | G2/G3 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 2650*930* 1110 | 700 | 770*770* 820 |
DL67.2/S603-F DD46.8/S603-F DJ29.0/S603-F | DL67.2/330B DD46.8/250B DJ29.0/170B | 6 | G2/G3 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 2650*1100* 1110 | 700 | 770*770* 820 |
DL83.4/S633-A DD56.2/S633-A DJ35.9/S633-A | DL83.4/410 DD56.2/310 DJ35.9/210 | 7.6 | G2/G4 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 3190*930* 1110 | 700 | 950*950* 1000 |
DL83.4/S603-F DD56.2/S603-F DJ35.9/S603-F | DL83.4/410 DD56.2/310 DJ35.9/210 | 7.6 | G2/G4 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 3190*1100* 1110 | 700 | 950*950* 1000 |
DL94.1/S633-A DD66.6/S633-A DJ40.8/S633-A | DL94.1/470 DD66.6/360 DJ40.8/240 | 8.7 | G2/G4 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 3280*930* 1210 | 700 | 980*980* 1030 |
DL94.1/S603-F DD66.6/S603-F DJ40.8/S603-F | DL94.1/470 DD66.6/360 DJ40.8/240 | 8.7 | G2/G4 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 3280*1100* 1210 | 700 | 980*980* 1030 |
DL110/S634-A DD77.7/S634-A DJ47.6/S634-A | DL110/550 DD77.7/420 DJ47.6/280 | 10 | G2/G4 | 4*φ630 | 4*850 (High-stretched and reinforced type ) | 4*10000 | 380 | Φ25 | Φ54 | 3780*930* 1210 | 700 | 860*860* 860*910 |
DL110/S604-F DD77.7/S604-F DJ47.6/S604-F | DL110/550 DD77.7/420 DJ47.6/280 | 10 | G2/G4 | 4*φ600 | 4*1500 (Air duct type) | 4*10000 | 380 | Φ25 | Φ54 | 3780*1100* 1210 | 700 | 860*860* 860*910 |
DL126/S634-A DD87.7/S634-A DJ54.4/S634-A | DL126/630 DD87.7/475 DJ54.4/320 | 11.5 | G2/G4 | 4*φ630 | 4*850 (High-stretched and reinforced type ) | 4*10000 | 380 | Φ25 | Φ54 | 3860*930* 1310 | 700 | 880*880* 880*930 |
DL126/S604-F DD87.7/S604-F DJ54.4/S604-F | DL126/630 DD87.7/475 DJ54.4/320 | 10.6 | G2/G4 | 4*φ600 | 4*1500 (Air duct type) | 4*10000 | 380 | Φ25 | Φ54 | 3860*1100* 1310 | 700 | 880*880* 880*930 |
Note: The tech. data is ba
Tech. data for Upgraded version electric defrosting evaporator
Upgraded version | old version | Defrost vlotage(kW) | Fan | Connection (mm) | Overall dimension (mm) | Installation dimension (mm) | ||||||
A Coil | B Catchment tray | Diameter (mm) | Vlotage (W) | Air flow (m3/h) | Voltage (V) | Inlet | Outlet | A*B*C | D | E1*E2*E3*E4 | ||
DL5.2/E352-A DD4.0/E352-A DJ2.3/E352-A | DL5.2/25 DD4.0/22 DJ2.3/15 | 0.8 | 0.8 | 2*φ350 | 2*135 (External Rotor Motor ) | 2*2670 | 380 | φ16 | Φ25 | 1160*450*610 | 360 | 880 |
DL8.2/E402-A DD6.0/E402-A DJ4.0/E402-A | DL8.2/40 DD6.0/30 DJ4.0/20 | 1 | 1 | 2*φ400 | 2*190 (External Rotor Motor ) | 2*3800 | 380 | φ16 | Φ25 | 1460*500*610 | 410 | 1180 |
DL11.5/E402-A DD8.0/E402-A DJ5.1/E402-A | DL11.5/55 DD8.0/40 DJ5.1/30 | 2 | 1 | 2*φ400 | 2*190 (External Rotor Motor ) | 2*3800 | 380 | φ16 | Φ25 | 1460*500*610 | 410 | 1180 |
DL16.7/E452-A DD12.0/E452-A DJ7.8/E452-A | DL16.7/80 DD12.0/60 DJ7.8/40 | 3.6 | 1.2 | 2*φ450 | 2*430 (High-stretched and reinforced type ) | 2*6800 | 380 | φ16 | φ32 | 1670*670*700 | 440 | 1380 |
DL22.0/E452-A DD15.9/E452-A DJ9.5/E452-A | DL22.0/105 DD15.9/80 DJ9.5/55 | 4.8 | 1.2 | 2*φ450 | 2*430 (High-stretched and reinforced type ) | 2*6800 | 380 | φ19 | φ32 | 1670*670*700 | 490 | 1380 |
DL25.8/E453-A DD20.0/E453-A DJ12.8/E453-A | DL25.8/125 DD20.0/100 DJ12.8/70 | 6 | 1.5 | 3*φ450 | 3*430 (High-stretched and reinforced type ) | 3*6800 | 380 | φ19 | φ38 | 2080*670*700 | 490 | 585*585*615 |
DL35.6/E453-A DD24.0/E453-A DJ15.7/E453-A | DL35.6/160 DD24.0/120 DJ15.7/85 | 7.2 | 1.8 | 3*φ450 | 3*430 (High-stretched and reinforced type ) | 3*6800 | 380 | φ19 | φ38 | 2450*670*700 | 490 | 710*710*740 |
DL38.5/E454-A DD28.0/E454-A DJ18.5/E454-A | DL38.5/185 DD28.0/140 DJ18.5/100 | 8.4 | 2.1 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ22 | Φ45 | 2800*670*700 | 490 | 620*620*620*650 |
DL44.0/E454-A DD32.1/E454-A DJ21.6/E454-A | DL44.0/210 DD32.1/160 DJ21.6/115 | 10.8 | 2.7 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ22 | Φ50 | 3160*670*700 | 490 | 710*710*710*740 |
DL52.5/E454-A DD37.4/E454-A DJ23.8/E454-A | DL52.5/260A DD37.4/200A DJ23.8/140A | 13.5 | 2.7 | 4*φ450 | 4*430 (High-stretched and reinforced type ) | 4*6800 | 380 | Φ25 | Φ50 | 3280*670*800 | 490 | 740*740*740*770 |
DL52.5/E632-A DD37.4/E632-A DJ23.8/E632-A | DL52.5/260B DD37.4/200B DJ23.8/140B | 11.2 | 1.6 | 2*φ630 | 2*850 (High-stretched and reinforced type ) | 2*10000 | 380 | Φ25 | Φ50 | 2190*880*900 | 640 | 925*975 |
DL52.5/E602-F DD37.4/E602-F DJ23.8/E602-F | DL52.5/260B DD37.4/200B DJ23.8/140B | 11.2 | 1.6 | 2*φ600 | 2*1500 (Air duct type) | 2*10000 | 380 | Φ25 | Φ50 | 2190*1030*900 | 640 | 925*975 |
DL67.2/E455-A DD46.8/E455-A DJ29.0/E455-A | DL67.2/330A DD46.8/250A DJ29.0/170A | 16.2 | 2.7 | 5*φ450 | 5*430 (Reinforced type) | 5*6800 | 380 | Φ25 | Φ50 | 3620*670*900 | 490 | 660*660*660 *600*690 |
DL67.2/E633-A DD46.8/E633-A DJ29.0/E633-A | DL67.2/330B DD46.8/250B DJ29.0/170B | 14 | 2 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 2650*880*900 | 640 | 770*770*820 |
DL67.2/E603-F DD46.8/E603-F DJ29.0/E603-F | DL67.2/330B DD46.8/250B DJ29.0/170B | 14 | 2 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 2650*1030*900 | 640 | 770*770*820 |
DL83.4/E633-A DD56.2/E633-A DJ35.9/E633-A | DL83.4/410 DD56.2/310 DJ35.9/210 | 17.5 | 2.2 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 3190*880*900 | 640 | 950*950*1000 |
DL83.4/E603-F DD56.2/E603-F DJ35.9/E603-F | DL83.4/410 DD56.2/310 DJ35.9/210 | 17.5 | 2.2 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 3190*1030*900 | 640 | 950*950*1000 |
DL94.1/E633-A DD66.6/E633-A DJ40.8/E633-A | DL94.1/470 DD66.6/360 DJ40.8/240 | 20 | 2.3 | 3*φ630 | 3*850 (High-stretched and reinforced type ) | 3*10000 | 380 | Φ25 | Φ50 | 3280*880*1000 | 640 | 980*980*1030 |
DL94.1/E603-F DD66.6/E603-F DJ40.8/E603-F | DL94.1/470 DD66.6/360 DJ40.8/240 | 20 | 2.3 | 3*φ600 | 3*1500 (Air duct type) | 3*10000 | 380 | Φ25 | Φ50 | 3280*1030*1000 | 640 | 980*980*1030 |
DL110/E634-A DD77.7/E634-A DJ47.6/E634-A | DL110/550 DD77.7/420 DJ47.6/280 | 20 | 2.3 | 4*φ630 | 4*850 (High-stretched and reinforced type ) | 4*10000 | 380 | Φ25 | Φ54 | 3780*880*1000 | 640 | 860*860*860*910 |
DL110/E604-F DD77.7/E604-F DJ47.6/E604-F | DL110/550 DD77.7/420 DJ47.6/280 | 20 | 2.3 | 4*φ600 | 4*1500 (Air duct type) | 4*10000 | 380 | Φ25 | Φ54 | 3780*1030*1000 | 640 | 860*860*860*910 |
DL126/E634-A DD87.7/E634-A DJ54.4/E634-A | DL126/630 DD87.7/475 DJ54.4/320 | 22.5 | 2.3 | 4*φ630 | 4*850 (High-stretched and reinforced type ) | 4*10000 | 380 | Φ25 | Φ54 | 3860*880*1100 | 640 | 880*880*880*930 |
DL126/E604-F DD87.7/E604-F DJ54.4/E604-F | DL126/630 DD87.7/475 DJ54.4/320 | 22.5 | 2.3 | 4*φ600 | 4*1500 (Air duct type) | 4*10000 | 380 | Φ25 | Φ54 | 3860*1030*1100 | 640 | 880*880*880*930 |
Note: The tech. data is ba