Home > Product

Electrical Defrost Evaporator

Download Get product quotation

  • Product description
  • Product parameters
  • Case

D series evaporator is a kind of cooling equipment suitable for various cold storages such as quick freezing fresh keeping and etc. There are three types available: DL DD and DJ which fits for the different cold temperatures. It has compact structure and make full use of warehouse area which can make the storage food cool rapidly and improve the freshness of storage food. DL type is suitable for fresh-keeping storehouse around O degree DD type suitable for chiller room around -18 degree DJ type is suitable for freezer room around -25 degree.

The features as follows:
● The evaporator are of reasonable structure uniform frosting and high efficiency heat exchange;
● The shell is made of quality steel with surface plastic-sprayedwhich is corrosion-resistant and beautiful;
● The evaporator are assembled with quality fan motor with low noise big air volume and stable operation;
● The evaporator adopt U-shaped stainless copper pipe evenly put into the fins which can shorten the defrosting time;
● The shell materials can be produced according to customer‘s requirement;
● The evaporator are tested under air pressure2. 5MPa guaranteeing the products' high gas tightness.

DL

Model Ref. capacity
(kW)
Cooling
Area
(m2)
Spacing of FinsFanDefrost heater
QtyDiameter
(mm)
Volume
(m3/h)
Pressure
(pa)
Fan motor
(n*w)
Power supplyCoil
(kW)
Catchment tray
(kW)
Power supply
DL-2.1/102.110.04.5130017009890220/380V 50Hz
1Ph/3Ph
0.50.50220V
50Hz
1Ph
DL-3.1/153.115.023002*1700982*900.70.70
DL-4.2/204.220.023002*1700982*900.80.80
DL-5.2/255.225.023502*2200982*140380V
50Hz
3Ph
1.01.00
DL-8.2/408.240.024002*34001182*1802.21.10
DL-11.5/5511.555.024002*34001182*1802.21.10
DL-16.7/8016.780.025002*60001672*5502.71.35
DL-22.0/10522.0105.025002*60001672*5504.01.35
DL-25.8/12525.8125.035003*60001673*5507.21.80
DL-35.6/16033.6160.035003*60001673*5508.82.20
DL-38.7/18538.7185.045004*60001674*55010.02.50
DL-44.0/21044.0210.045004*60001674*55011.22.80
DL-52.9/260(A)52.9260.045004*60001674*55014.02.80
DL-52.9/260(B)52.9260.026002*100002002*110012.61.80
DL-67.2/330(A)67.2330.045504*75001804*75016.82.80
DL-67.2/330(B)67.2330.036003*100002003*110015.52.20
DL-83.4/41083.4410.036003*100002003*110018.22.60
DL-86.0/44086.0440.036003*100002003*150019.62.80
DL-91.0/46091.0460.036503*120002103*220020.82.60
DL-97.5/50097.5500.036504*120002103*220022.42.80
DL-105.0/540105.0540.046004*100002004*110022.42.80
DL-111.0/570111.0570.046004*100002004*110022.42.80
DL-117.0/600117.0600.046504*120002104*220025.22.80
DL-125.0/640125.0640.046504*120002104*220025.22.80
DL-129.0/665129.0665.046504*120002104*220025.22.80
DL-133.0/700133.0700.046504*120002104*220028.05.60
DL-140.0/735140.0735.046504*120002104*220028.05.60
DL-147.0/775147.0775.046504*120002104*220033.55.60
DL-152.0/800152.0800.046504*120002104*220033.55.60


DD

ModelRef. capacity
(kW)
Cooling Area
(m2)
Spacing of FinsFanDefrost heater
QtyDiameter
(mm)
Volume
(m3/h)
Pressure
(pa)
Fan motor
(n*w)
Power supplyCoil
(kW)
Catchment tray
(kW)
Power supply
DD-1.4/71.4076130017009890220/380V
50Hz
1Ph/3Ph
0.50.50220V
50Hz
1Ph
DD-2.35/122.351223002*1700982*900.70.70
DD-3.0/153.001523002*1700982*900.80.80
DD-4.0/224.002223502*2200982*140380V
50Hz
3Ph
1.01.00
DD-6.0/306.003024002*34001182*1802.21.10
DD-8.0/408.004024002*34001182*1802.21.10
DD-12.0/6012.006025002*60001672*5504.01.35
DD-15.9/8015.908025002*60001672*5505.41.35
DD-20.0/10020.0010035003*60001673*5509.01.80
DD-24.0/12024.0012035003*60001673*55011.02.20
DD-28.0/14028.0014045004*60001674*55012.52.50
DD-32.1/16032.1016045004*60001674*55014.02.80
DD-37.4/200(A)37.4020045004*60001674*55016.82.80
DD-37.4/200(B)37.4020026002*100002002*150014.41.80
DD-46.8/250(A)46.8025045504*75001804*75019.62.80
DD-46.8/250(B)46.8025036003*100002003*150017.62.20
DD-56.2/31056.2031036003*100002003*150020.82.60
DD-59.4/33059.4033036003*100002003*150022.42.80
DD-64.7/35064.7035036503*120002103*220026.02.60
DD-68.4/38068.4038036503*120002103*220028.02.80
DD-72.0/40072.0040046004*100002004*150028.02.80
DD-76.5/42576.5042546004*100002004*150028.02.80
DD-81.0/45081.0045046504*120002104*220031.02.80
DD-86.5/48086.5048046504*120002104*220031.02.80
DD-90.0/50090.0050046504*120002104*220031.02.80
DD-93.0/53093.0053046504*120002104*220035.45.60
DD-96.0/55096.0055046504*120002104*220035.45.60
DD-101.0/580101.0058046504*120002104*220040.05.60
DD-105.0/600105.0060046504*120002104*220040.05.60


DJ

ModelRef. capacity
(kW)
Cooling Area
(m2)
Spacing of FinsFanDefrost heater
QtyDiameter
(mm)
Volume
(m3/h)
Pressure
(pa)
Fan motor
(n*w)
Power supplyCoil
(kW)
Catchment tray
(kW)
Power supply
DJ-1.2/71.207923002*1700982*90220/380V 50Hz 1Ph/3Ph0.70.7220V
50Hz
1Ph
DJ-1.32/101.321023002*1700982*1400.80.8
DJ-2.3/152.301523502*2200982*1401.01.0
DJ-4.0/204.002024002*34001182*1802.21.1
DJ-5.1/305.103024002*34001182*180380V
50Hz
3Ph
2.21.1
DJ-7.8/407.804025002*60001672*5504.01.4
DJ-9.5/559.505525002*60001672*5505.41.4
DJ-12.8/7012.807035003*60001673*5509.01.8
DJ-15.7/8515.708535003*60001673*55011.02.2
DJ-18.5/10018.5010045004*60001674*55012.52.5
DJ-21.6/11521.6011545004*60001674*55014.02.8
DJ-23.8/140(A)23.8014045004*60001674*55016.82.8
DJ-23.8/140(B)23.8014026002*1000032002*150014.41.8
DJ-29.0/170(A)29.0017045504*75001804*75019.62.8
DJ-29.0/170(B)29.0017036003*100002003*150017.62.2
DJ-35.9/21035.9021036003*100002003*150020.82.6
DJ-38.0/22538.0022536003*100002003*150022.42.8
DJ-39.8/23539.8023536503*120002103*220026.02.6
DJ-43.2/25543.2025536503*120002103*220028.02.8
DJ-47.6/28047.6028046004*100002004*150028.02.8
DJ-50.0/29550.0029546004*100002004*150028.02.8
DJ-52.7/31052.7031046504*120002104*220031.02.8
DJ-56.0/33056.0033046504*120002104*220031.02.8
DJ-58.5/34558.5034546504*120002104*220031.02.8
DJ-60.0/36560.0036546504*120002104*220035.45.6
DJ-63.0/38063.0038046504*120002104*220035.45.6
DJ-66.0/40066.0040046504*120002104*220040.05.6
DJ-68.0/41568.0041546504*120002104*220040.05.6


The overall and installation dimension for ceilling type evaporator

ModelABCDEE1E2E3FInlet tube
(mm)
Back trachea
(mm)
Drainpipe
DL-2.1/10730390460270530///951219G1"
DD-1.4/7
DL-3.1/15980390460270780///
DD-2.35/12
DJ-1.2/7
DL-4.2/201130390460270930///
DD-3.0/15
DJ-1.32/10
DL-5.2/2513104604603301080///1222
DD-4.0/22
DJ-2.3/15
DL-8.2/4015104905503601230///1625
DD-6.0/30
DJ-4.0/20
DL-11.5/5515104905503601230///
DD-8.0/40
DJ-5.1/30
DL-16.7/8018106706604601530750//1935
DD-12.0/60
DJ-7.8/40
DL-22.0/10518106706604601530750//
DD-15.9/80
DJ-9.5/55
DL-25.8/12522906706604602010660660/38
DD-20.0/100
DJ-12.8/70
DL-35.6/16027106706604602430800800/
DD-24.0/120
DJ-15.7/85
DL-38.7/185311067066046028307007007002550G1"1/2
DD-28.0/140
DJ-18.5/100
DL-44.0/21035106706604603230800800800
DD-32.1/160
DJ-21.6/115
DL-52.5/260(A)35106906905103230800800800
DD-37.4/200(A)
DJ-23.8/140(A)
DL-52.9/260(B)22109608606301950950//
DD-37.4/200(B)
DJ-23.8/140(B)


Contact Us (*Must fill in)