Home > Product

Box U Type Condensing Units

Download Get product quotation

  • Product description
  • Product parameters
  • Case

● The shell is of box structure with secure connection and the compressor power is power is from 1hp~30hpwhich is suitable for both the hermetic and semi-hermetic compressors in various brands;
● All the units are tested under 2.8Mpa gas tightness and pollution discharge which is suitable for R22、R134a、R404a、R407c refrigerants etc;
● FUN type condenser is of wide surface with excellent performance in heat exchanging which is widely used for various condensing units;
● All the fans are axial fans which is easy for installation and maintenance with stable operation and low noise.


Model code:
RX -FNU-10MH(L)
RX: Brand RX
FNU:Type of air-cooled condenser:U type
10:Nominal horse power HP
MH:Mid and high temperature
ML:Mid and low temperature

Tech.data for Box U type condensing units

Medium and high temperature air-cooled condensing unit
Model of unitsRX-FNU-03MHRX-FNU-05MHRX-FNU-06MHRX-FNU-07MHRX-FNU-08MH
Compressor modelZB21KQZB38KQZB45KQZB48KQZB58KQ
Applicable Temperature(℃)-5℃ ~ -15℃
RefrigerantR22 / R404A
Power supply380V 50HZ
CondenserQuantity of Fan(pcs)12222
Power of Fan1*2302*1902*2302*2302*320
Ref.Capacity of
condensing units
Evaporating Temperature
-5℃
Ref. Capacity(w)5820/57409710/983011750/1150012950/1300015100/15300
Power(w)2240/25003610/41804210/47304630/54105460/6360
Evaporating Temperature
-12℃
Ref. Capacity(w)4350/43007260/73708840/86309730/980010900/11350
Power(w)2220/25103570/42004150/47604570/51505470/6320
CouplingTube couplingφ12φ12φ12φ16φ16
Suction couplingφ19φ22φ22φ22φ22
Overall dimensionLenght (A) mm7501130125012501350
Width (B) mm730730730730730
Height (H) mm950950115011501050
Installation dimension(D*E)mm500*690830*690900*690900*690950*690
Medium and high temperature air-cooled condensing unit
Model of unitsRX-FNU-09MHRX-FNU-10MHRX-FNU-12MHRX-FNU-13MHRX-FNU-15MH
Compressor modelZB66KQZB76KQZB88KQZB95KQZB114KQ
Applicable Temperature(℃)-5℃ ~ -15℃
RefrigerantR22 / R404A
Power supply380V 50HZ
CondenserQuantity of Fan(pcs)22222
Power of Fan(w)2*3202*3202*3502*3502*380
Ref.Capacity of condensing unitsEvaporating Temperature
-5℃
Ref. Capacity(w)17500/1710020600/204002350024700/2500029500/29700
Power(w)6030/70907130/829080709110/1070010800/12650
Evaporating Temperature
-12℃
Ref. Capacity(w)13100/1285015450/152501755017550/1860021100/21900
Power(w)5970/70407040/819079708940/1060010750/12650
CouplingTube couplingφ16φ16φ16φ16φ16
Suction couplingφ35φ35φ35φ35φ35
Overall dimensionLenght (A) mm13501350150015001600
Width (B) mm730830830830830
Height (H) mm10501100115012001350
Installation dimension(D*E)mm950*690950*790950*790950*7901000*790



Medium and high temperature air-cooled condensing unit
Model of unitsRX-FNU-03RX-FNU-04RX-FNU-05RX-FNU-06RX-FNU-07
Compressor model2DES-32CES-44FES-54EES-64DES-7
Applicable Temperature(℃)-5℃ ~ -15 ℃
RefrigerantR22/R404A
CondenserQuantity of Fan(pcs)12222
Power of Fan(w)1*2302*1902*1902*2302*230
Ref.Capacity of condensing unitsEvaporating Temperature
-5℃
Ref. Capacity(w)8020/83009880/1025010530/1111013400/1396016010/16890
Power(w)2970/33103650/40703830/43803830/43805800/6620
Evaporating Temperature
-15℃
Ref. Capacity(w)5240/55206500/68706810/73706810/737010460/11190
Power(w)2530/27803120/34403250/37603250/37604940/5640
CouplingTube couplingφ12φ12φ12φ12φ16
Suction couplingφ22φ22φ22φ22φ28
Overall dimensionLenght (A) mm8501130113012501250
Width (B) mm730730730730730
Height (H) mm950950105011501000
Installation dimension(D*E)mm600*690830*690900*690900*690900*690
Medium and high temperature air-cooled condensing unit
Model of unitsRX-FNU-10RX-FNU-12RX-FNU-15RX-FNU-20RX-FNU-25
Compressor model4VES-104TES-124PES-154NES-204HE-25
Applicable Temperature(℃)-5℃ ~ -15 ℃
RefrigerantR22/R404A
CondenserQuantity of Fan(pcs)22222
Power of Fan(w)2*3202*3202*3502*5802*580
Ref.Capacity of condensing unitsEvaporating Temperature
-5℃
Ref. Capacity(w)21300/2130025700/2580029400/2940034800/3520046400/46500
Power(w)7210/80108830/986010050/1117011810/1332015860/17590
Evaporating Temperature
-15℃
Ref. Capacity(w)13620/1373016580/1678018730/1883022300/2290030000/30800
Power(w)6020/65807390/81308320/90909860/1100013330/14700
CouplingTube couplingφ16φ16φ16φ22φ22
Suction couplingφ28φ35φ35φ42φ54
Overall dimensionLenght (A) mm13501500150016001800
Width (B) mm830830830880880
Height (H) mm11001100125014501550
Installation dimension(D*E)mm950*790950*790950*7901000*8401000*840
Medium and High Temperature Air-Cooled Condensing Unit Semi-hermetic Series
Model of unitsRX-FNU-14RX-FNU-18MLRX-FNU-23MLRX-FNU-28MLRX-FNU-34ML
Compressor model4NES-144HE-184GE-234HE-286GE-4
Applicable Temperature(℃)-20℃ ~ -35 ℃
RefrigerantR22/R404A
CondenserQuantity of Fan(pcs)22222
Power of Fan(w)2*3202*3502*5802*5802*580
Ref.Capacity of condensing unitsEvaporating Temperature
-25℃
Ref. Capacity(w)13490/1395017170/1988019920/2340025800/2930029900/35400
Power(w)7880/858010420/1200012490/1427015610/1769018700/21800
Evaporating Temperature
-35℃
Ref. Capacity(w)10020/1052012610/1532014670/1824018920/2260022000/27800
Power(w)6800/72408920/1035010770/1233013370/1520016130/18950
CouplingTube couplingφ16φ22φ22φ22φ22
Suction couplingφ35φ42φ54φ54φ54
Overall dimensionLenght (A) mm13501350150016001800
Width (B) mm730830830880880
Height (H) mm10501100125014501550
Installation dimension(D*E)mm950*690950*790950*7901000*8401000*840