● The shell is designed as box type and the ba
● It is stronger and more stable with little vibration comparing with the common box V type condensing units ;
● Heat exchange area is available from 80-500m2 which is suitable for both hermetic and semi-hermetic compressors in various brands;
● There are 7 fan blades to fit on the 6-stage axial fans with stable operation and low noise.
Model code:
RX -FNV-15MH(L)
RX: Brand RX
FNV:Type of air-cooled condenser:V type
15:Nominal horse power HP
MH:Mid and high temperature
ML:Mid and low temperature
Tech.data for Box V /W type condensing units(left and right whole)
Model | Heat exchange capacity (kW) | Fan | Inlet pipe/ Outlet pipe(mm) | Overall dimension(mm) | Installation dimension(mm) | |||||
Power (w) | Diameter (mm) | Air volume (m3/h) | Vlotage (v) | Inlet tube (mm) | Back trachea (mm) | A*B*H | D | E | ||
FNV-100 | 31.0 | 2*230 | 2*450 | 10000 | 380 | 25 | 19 | 2110*880*920 | 1710 | 830 |
FNV-120 | 37.2 | 2*320 | 2*500 | 13200(7stage6blades) | 380 | 28 | 22 | 2310*880*940 | 1910 | 830 |
FNV-130 | 40.3 | 2*320 | 2*500 | 13200(7stage6blades) | 380 | 28 | 22 | 2410*880*940 | 2010 | 830 |
FNV-140 | 43.4 | 2*320 | 2*500 | 13200(7stage6blades) | 380 | 28 | 22 | 2510*880*940 | 2110 | 830 |
FNV-160 | 49.6 | 2*350 | 2*550 | 16000(7stage6blades) | 380 | 32(35) | 22 | 2760*880*940 | 2360 | 830 |
FNV-180 | 55.8 | 2*580 | 2*630 | 22800(7stage6blades) | 380 | 32(35) | 22 | 2510*1070*1140 | 2110 | 1020 |
FNV-200 | 62.0 | 2*580 | 2*630 | 22800(7stage6blades) | 380 | 35 | 25 | 2710*1070*1140 | 2310 | 1020 |
FNV-220 | 68.2 | 2*580 | 2*630 | 22800(7stage6blades) | 380 | 35 | 25 | 2860*1070*1140 | 2460 | 1020 |
FNV-250 | 77.5 | 3*350 | 3*550 | 24000(7stage6blades) | 380 | 35 | 25 | 3210*1070*1140 | 2810 | 1020 |
FNV-285 | 88.3 | 3*580 | 3*630 | 34200(7stage6blades) | 380 | 35 | 25 | 3510*1070*1140 | 2710 | 1020 |
FNV-300 | 93.0 | 3*580 | 3*630 | 34200(7stage6blades) | 380 | 35 | 25 | 3660*1070*1140 | 2860 | 1020 |
FNV-320 | 98.0 | 3*550 | 3*630 | 31200(7stage6blades) | 380 | 35 | 25 | 3250*1120*1140 | 2850 | 1055 |
FNV-340 | 105.0 | 3*580 | 3*630 | 34200(7stage6blades) | 380 | 35 | 25 | 3370*1120*1140 | 2570 | 1055 |
FNV-380 | 113.0 | 3*580 | 3*630 | 34200(7stage6blades) | 380 | 42 | 28 | 3610*1120*1140 | 2810 | 1055 |
FNV-430 | 129.0 | 4*550 | 4*600 | 41600(7stage6blades) | 380 | 42 | 28 | 3930*1120*1140 | 3130 | 1055 |
Medium and High Temperature Air-Cooled Condensing Unit Semi-hermetic Series | ||||||||
Model of units | RX-FNV-10 | RX-FNV-12 | RX-FNV-15 | RX-FNV-20 | RX-FNV-25 | RX-FNV-30 | ||
Compressor model | 4VES-10 | 4TES-12 | 4PES-15 | 4NES-20 | 4HE-25 | 4GE-30 | ||
Applicable Temperature(℃) | -5℃ ~ -15℃ | |||||||
Refrigerant | R22 / R404A | |||||||
Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 2 | 3 | 3 | |
Power of Fan (w) | 2*320 | 2*320 | 2*350 | 2*580 | 3*350 | 3*580 | ||
Ref.Capacity of condensing units | Evaporating Temperature -5℃ | Ref. Capacity(w) | 21300/21300 | 25700/25800 | 29400/29400 | 34800/35200 | 46400/46500 | 53800/53300 |
Power(w) | 7210/8010 | 8830/9860 | 10050/11170 | 11810/13320 | 15860/17590 | 18280/20300 | ||
Evaporating Temperature -15℃ | Ref. Capacity(w) | 13620/13730 | 16580/16780 | 18730/18830 | 22300/22900 | 30000/30800 | 35000/35500 | |
Power(w) | 6020/6580 | 7390/8130 | 8320/9090 | 9860/11000 | 13300/14700 | 15400/16990 | ||
Coupling | Tube coupling | 16 | 16 | 16 | 19 | 22 | 22 | |
Suction coupling | 28 | 35 | 42 | 42 | 54 | 54 | ||
Overall dimension | Lenght (A) mm | 2310 | 2410 | 2760 | 2710 | 3210 | 3660 | |
Width (B) mm | 880 | 880 | 880 | 1070 | 1070 | 1070 | ||
Height (H) mm | 940 | 940 | 940 | 1140 | 1140 | 1140 | ||
Installation dimension(D*E)mm | 1910*830 | 2010*830 | 2360*830 | 2310*1020 | 2810*1020 | 2860*1020 |
Condensing machine semi-closed
Low temperature Air-Cooled Condensing Unit Semi-hermetic Series | |||||||
Model of units | RX-FNV-14ML | RX-FNV-18ML | RX-FNV-23ML | RX-FNV-28ML | RX-FNV-34ML | ||
Compressor model | 4NES-14 | 4HE-18 | 4GE-23 | 6HE-28 | 6GE-34 | ||
Applicable Temperature℃ | -20℃ ~ -35℃ | ||||||
Refrigerant | R22 / R404A | ||||||
Condenser | Quantity of Fan(pcs) | 2 | 2 | 2 | 2 | 3 | |
Power of Fan (w) | 2*320 | 2*320 | 2*350 | 2*580 | 3*350 | ||
Ref.Capacity of condensing units | Evaporating Temperature -25℃ | Ref. Capacity(w) | 13490/13950 | 17170/19880 | 19920/23400 | 25800/29300 | 29900/35400 |
Power(w) | 7880/8580 | 10420/12000 | 12490/14270 | 15610/17690 | 18720/21800 | ||
Evaporating Temperature -30℃ | Ref. Capacity(w) | 10020/10520 | 12610/15320 | 14670/18240 | 18920/22600 | 22000/27800 | |
Power(w) | 6800/7240 | 8920/10350 | 10770/12330 | 13370/15200 | 16130/18950 | ||
Coupling | Tube coupling | 16 | 16 | 22 | 22 | 22 | |
Suction coupling | 35 | 42 | 54 | 54 | 54 | ||
Overall dimension | Lenght (A) mm | 2110 | 2310 | 2760 | 2710 | 3210 | |
Width (B) mm | 880 | 880 | 880 | 1070 | 1070 | ||
Height (H) mm | 920 | 940 | 940 | 1140 | 1140 | ||
Installation dimension(D*E)mm | 1710*830 | 1910*830 | 2360*830 | 2310/1020 | 2810/1020 |
Next:Box H Type Condensing Units